Posted on

OAK Appliance user manual – Part 2

Add an outgoing call rule that makes the outgoing calls from the internal phone

The example scenario is: 

  • Internal phone: extension number 6001, suppose you have created in part 1
  • Analog external FXO: PSTN lines 1, suppose you have created in part 1
  • Dial 010000 to access external PSTN line, also strip the first digital 0, therefore the PSTN line will only can see 10000

Go to the Call Routing -> Outgoing Calling Routing -> New Calling Rule, the Create New Calling Rule will show up as below

Create New Calling Rule

The name is ToPSTN, fill up the Number Starts With to 0, selected the Any Length, then click the Call Routing button that located the top middle

Select the Select Primary & Fallover External Lines, and choose the Primary External Line to you have created an external PSTN line that as the above picture shows. Also, fill up the Strip field to 1 that means to remove the first digital 0 in our test scenario defined. Click Save button.

ToPSTN calling rule is created

Go to the PBX Configuration -> select the 6001 and click the edit icon

change the Outgoing Calling Rule Set to that you just created ToPSTN, then click Save, and Click the Apply Changes, the system will prompt you to reboot the device, reboot it, you should able to dial 010000 to get the call go to outside.